Due to long-term tunnel operations in high-temperature environments, the increase in body temperature can cause symptoms such as heat stroke and dehydration. In severe cases, it may even endanger life. Working in such an environment can lead to reduced work efficiency, decreased work quality, and increased risk of accidents due to inattention and uncoordinated movements. In response to the above situation, our company has designed and developed tunnel cooling equipment.
The equipment meets the cooling demand of the tunnel 45℃-26℃ (about 1 hour);
Maximum applicable section 120㎡ (high 9 meters, wide 14 meters);
Maximum conveying capacity 200 m (cold air);
Mobility: equipped with well-known manufacturers' car chassis;
Data acquisition: real-time data acquisition can be transmitted to third-party platforms;
parameter | ||
order number | Parameter name | technical parameter |
1 | Maximum cooling capacity | ≥280kW |
2 | maximum quantity of wind | ≥48000m³/h |
3 | Temperature control range | 30℃-15℃ |
4 | Cooling efficiency | Return air 43℃ -cold air outlet 28℃ |
5 | Power supply | AC380V(50Hz) |
6 | interiorinput power | 137kw |
7 | Cable length | 60m |
8 | engine power | 257kW |
9 | Maximum turning radius | 12m |
10 | speed of travel | ≥89km/h |
11 | External dimensions (length * width * height) | 10030*2500*3500mm |
12 | Overall weight | 12500kg |